º»¹® ¹Ù·Î°¡±â

¼­ºêÆäÀÌÁö ÄÜÅÙÃ÷

ÁÖ¿ä»ç¾÷ ±¹Á¦°øÀνÃÇè±â°ü¿î¿µ ½ÃÇè¼³ºñÇöȲ

½ÃÇè¼³ºñÇöȲ

ÁÖ¿äÀåºñ

°ü·Ã¹®ÀÇ
Àåºñ¸í »çÁø ¸ðµ¨¸í »ç¾ç Á¦ÀÛ»ç µµÀԽñâ
Àü·ÂÃøÁ¤±â
(Ãâ·Â¼º´É
ÃøÁ¤¿ë)
Àü·ÂÃøÁ¤±âÃâ·Â¼º´É ÃøÁ¤¿ë DEWE638 Channel : 4voltage, 4current
Input Voltage(Accuracy: ¡¾0.02%): 200V, 400V, 800V, 1400V
Input Current(Accuracy: ¡¾0.05%): 1A, 3A, 10A
DEWETRON 2013³â
Àü·ÂÃøÁ¤±â
(Àü·ÂÇ°Áú
ÃøÁ¤¿ë)
Àü·ÂÃøÁ¤±â Àü·ÂÇ°Áú ÃøÁ¤¿ë DEWE2600 8 Channel : HV 4EA, LV 4EA HSI modules
Input HV(Accuracy: ¡¾0.05%): 200V, 400V, 800V, 1400V
Input LV(Accuracy: ¡¾0.05%): 2.5V, 5V, 10V, 25V, 50V
DEWETRON 2013³â
Àü·Â½ÅÈ£
º¯È¯±â
(±â°èÇÏÁß
ÃøÁ¤¿ë)
Àü·Â½ÅÈ£º¯È¯±â ±â°èÇÏÁß ÃøÁ¤¿ë P530 Nominal input current : 1 to 6A
Nominal input voltage : 100 to 690V
Accuracy : Class 0.5
Camille BAUER 2014³â
Àü¾Ð±â·Ï°è Àü¾Ð±â·Ï°è Q.Bloxx A106 Input : A/I 2EA(strain gauge, etc) ,
D/I 4EA (max.30VDC, max.0.5mA)
Output : A/O 2EA(¡¾10 V, 10kHz) / D/O 4EA(state, alarm, limit switch)
Accuracy : 0.02%(typical),
Gantner 2014³â
Àü¾Ð±â·Ï°è Àü¾Ð±â·Ï°è Q.Bloxx A108 Input: A/I 8EA(¡¾10V) / max.dev.:¡¾2V,
D/I 2EA (max.30VDC,max.0.5mA) , Output: D/O 2EA(state, alarm)
Accuracy : 0.01%(typical)
Gantner 2014³â
µðÁöÅÐ
±â·Ï°è
µðÁöÅбâ·Ï°è Q.Bloxx D101 Input: D/I 8EA(max.30VDC, max. 2mA)
Signal Volt.¡®0¡¯:(-3~5)VDC, Signal Volt.¡®1¡¯:(11~30)VDC
Accuracy : 0.1%
Gantner 2014³â
µðÁöÅÐ
±â·Ï°è
µðÁöÅбâ·Ï°è Q.Bloxx D104 Input:D/I16EA(max.30VDC, max. 2mA)
Signal Volt.¡®0¡¯:(-3~5)VDC, Signal Volt.¡®1¡¯:(11~30)VDC
Gantner 2014³â
ÇÏÁßÃøÁ¤
DAQ
ÁßÃøÁ¤DAQ Q.station RAM:1GB, Flash:4GB, OS:Real Time Linux, Ethernet interface(Isolation 500V), CAN,RS485 slave interface Gantner 2014³â
ÅÚ·¹¸ÞÆ®¸®
Decorder
ÅÚ·¹¸ÞÆ®¸®Decorder TEL1-PCM-DEC Input:via 7pol(Àü¿ë sensor)
Output : ¡¾10V(optional 4mA~20mA)
Accuracy : ¡¾0.2%, Operating temp. : -10¡É~70¡É
KMT 2014³â
¼ÒÀ½ÃøÁ¤¿ë
ÄŠdz¼Ó°è
¼ÒÀ½ÃøÁ¤¿ë ÄŠdz¼Ó°è P6140H Measurement range : 0.5m/s~50m/s
Accuracy : ¡¾3%(¡Ã0.5m/s ÀÌ»ó), Resolution : <0.1m/s
Survival wind speed : max. 60m/s, Ambient temp. : -30¡É~70¡É
ThiesClima 2014³â
¼ÒÀ½ÃøÁ¤¿ë
dzÇâ°è
¼ÒÀ½ÃøÁ¤¿ëdzÇâ°è P6145H Measurement range : 0¡Æ~360¡Æ
Accuracy : ¡¾2¡Æ, Resolution : 0.5¡Æ
Survival wind speed : max. 80m/s, Ambient temp. : -40¡É~70¡É
ThiesClima 2014³â
¼ÒÀ½ÃøÁ¤¿ë
´ë±â¾Ð°è
¼ÒÀ½ÃøÁ¤¿ë´ë±â¾Ð°è DO2003 R Measurement range : 600hpa~900hpa
Accuracy : ¡¾1hpa(at 20¡É), Resolution : 1hpa
Ambient temp. : -10¡É~60¡É
DELTA OHM 2014³â
¼ÒÀ½ÃøÁ¤¿ë
¿Â¡¤½Àµµ°è
¼ÒÀ½ÃøÁ¤¿ë ¿Â¡¤½Àµµ°è DO2003 R Measurement range : -20¡É~80¡É, Accuracy : ¡¾0.3¡É Resolution : 0.1¡É
Measurement range : (0~100)% R.H., Accuracy : ¡¾2%, Resolution : 0.1% R.H., Ambient temp. : -40¡É~150¡É
DELTA OHM 2014³â
¼ÒÀ½ÃøÁ¤¿ë
±â»óµ¥ÀÌÅÍ
·Î°Å
¼ÒÀ½ÃøÁ¤¿ë»óµ¥ÀÌÅÍ ·Î°Å CR1000  Input : A/I 8EA(¡¾5V, etc.), D/I 8EA(3.8V~16V)
 Output : ¡¾2.5V(0.67mV resol.), Accuracy : ¡¾0.06%
Pulse counters : 2EA(24bit), Processor : 16bit CPU(with 32bit internal core), 4Mbytes SRAM, RS232 interface
Cambell scientific INC. 2014³â
¼ÒÀ½ÃøÁ¤±â ¼ÒÀ½ÃøÁ¤±â Hand-held Analyzer 2270  Input:2 channel, ÁÖÆļö °¡Áß:A,B,C µî 5°¡Áö Àû¿ë°¡´É, Sound level meter S/W: IEC61672 class1, IEC60651 Type1
FFT analysis: IEC61260 class0 1/1-octave bands&1/3-octave bands  USB¡¤LAN interface, SD memory card(storage)
BNK 2014³â